Buy 1V LSD 150mcg Blotters
$38.00 – $490.00Price range: $38.00 through $490.00
Product Short Description
1V-LSD 150mcg Blotters is a brandless, generic lysergamide research chemical with ≥98% purity, supplied for analytical laboratory applications. This high-purity compound serves as a reference standard in controlled research settings. For research use only. Not for human or veterinary use. Not for clinical, diagnostic, or consumptive applications.
Product Overview
1V-LSD 150mcg Blotters represents a premium, brandless research chemical formulated exclusively for advanced laboratory and analytical investigations within the field of N-acylated lysergamides. Classified as (6aR,9R)-N,N-diethyl-7-methyl-4-pentanoyl-6,6a,8,9-hexahydroindolo[4,3-fg]quinoline-9-carboxamide (CAS 3028950-70-8), this ≥98% purity compound enables precise analytical work in synthetic chemistry and reference material studies. Offered as a generic reagent on blotter substrate, it supports researchers in exploring structural analogs and chromatographic standards under strictly controlled conditions. For research use only. Not for human or veterinary use. Not for clinical, diagnostic, or consumptive applications.
The blotter delivery format facilitates accurate microgram-level sampling and integration into high-throughput laboratory protocols, ensuring consistency across experimental replicates. Qualified research facilities utilize such compounds to benchmark instrument performance and validate method development in forensic, pharmaceutical, and materials science contexts. This product upholds rigorous standards for purity and documentation, positioning it as a reliable choice for institutions prioritizing compliance and reproducibility in their analytical workflows.
Chemical Identity & Classification
1V-LSD corresponds to the systematic name (6aR,9R)-N,N-diethyl-7-methyl-4-pentanoyl-4,6,6a,7,8,9-hexahydroindolo[4,3-fg]quinoline-9-carboxamide, with primary identifiers including CAS number 3028950-70-8, molecular formula C₂₅H₃₃N₃O₂, and molecular weight 407.55 g/mol. Common synonyms encompass 1-valeroyl-LSD, “Valerie”, and 1V-LSD, reflecting its position within the lysergamide family as an N1-pentanoyl derivative of LSD. As a synthetic reference material, it functions as an analytical reagent for identification and quantification in complex matrices.
This compound belongs to the lysergamide class, distinguished by a valeroyl (pentanoyl) acyl group substitution on the indole nitrogen of the LSD scaffold. Laboratories classify it under novel psychoactive substance references in certain jurisdictions, necessitating adherence to regulatory protocols for handling and documentation. Its chemical profile supports applications in mass spectrometry libraries and NMR spectral databases, aiding in the characterization of structurally related N-acyl lysergamides.
Chemical & Physical Characteristics
1V-LSD appears as a crystalline solid adsorbed onto laboratory-grade blotter paper at 150mcg per unit, exhibiting high uniformity for analytical sampling. The compound demonstrates solubility in polar organic solvents such as methanol and acetonitrile, with stability enhanced in its protonated forms typical for lysergamide analysis. Thermal profiles support vaporization or desorption techniques for GC-MS profiling, displaying characteristic amide fragmentation patterns.
Stability remains favorable under desiccated, light-protected conditions, with minimal hydrolysis observed in inert atmospheres. The lysergamide structure confers UV absorbance maxima suitable for HPLC detection at 220–320 nm, including the signature tetracyclic isoindole chromophore. Blotter substrate ensures precise microgram-level deposition integrity, resisting migration during storage or handling in analytical protocols.
Purity & Analytical Verification
Each batch of 1V-LSD 150mcg Blotters achieves or exceeds ≥98% purity, verified through orthogonal analytical techniques including high-performance liquid chromatography (HPLC), gas chromatography (GC), nuclear magnetic resonance (NMR) spectroscopy, and liquid chromatography-mass spectrometry (LC-MS). These methods quantify primary substance content while identifying and limiting impurities to trace levels, typically below 0.5% for related lysergamides and 0.1% for residual solvents. Certificate of Analysis (COA) documentation accompanies every lot, detailing retention times, peak areas, and spectral data for full transparency.
HPLC analysis employs reversed-phase C18 columns with gradient elution, achieving baseline resolution of N-acyl isomers and degradation products. NMR confirms stereochemical integrity through diagnostic valeroyl methylene signals and ethyl amide patterns, while LC-MS provides high-resolution mass confirmation of the [M+H]⁺ ion at m/z 408.265. Such comprehensive verification ensures batch-to-batch reproducibility, critical for reference standard applications in quantitative assays.
Quality Control & Batch Integrity
Production follows batch-controlled processes with full lot traceability from synthesis through blotter impregnation and final packaging, utilizing unique alphanumeric identifiers for each production run. Internal quality assurance includes multi-stage sampling and third-party independent laboratory validation to confirm compliance with ≥98% purity specifications and uniform deposition. Documentation standards encompass detailed batch records, stability data, and impurity profiles, accessible via COA upon request.
This rigorous framework mitigates variability, ensuring every 1V-LSD 150mcg Blotter shipment meets specifications for sensitive research demands. Tamper-evident seals and serialized labeling further enhance chain-of-custody integrity, supporting institutional audit requirements and regulatory submissions. Researchers benefit from this systematic approach, which prioritizes reliability in long-term studies or method transfers across laboratories.
Safety, Handling & Laboratory Precautions
Handling of 1V-LSD 150mcg Blotters requires standard laboratory personal protective equipment (PPE), including nitrile gloves, safety goggles, and laboratory coats, within certified fume hoods or controlled environments. Trained personnel must adhere to institutional safety protocols, avoiding direct skin contact or inhalation through engineered controls and administrative safeguards. Material Safety Data Sheet (MSDS/SDS) provides detailed hazard classifications, exposure limits, and spill response procedures, available with each order.
Work surfaces should feature secondary containment, with waste disposal following local chemical regulations for lysergamide-class compounds. Emergency eyewash stations and spill kits remain essential near handling areas. These precautions ensure safe integration into laboratory operations without implying any consumptive safety assessments.
Packaging, Labeling & Storage
1V-LSD 150mcg Blotters arrive in professional research-grade packaging, featuring tamper-resistant, light-proof foil pouches or HDPE containers protecting individual or sheeted blotters from moisture and photodegradation. Compliant labeling includes product name, CAS number, purity statement, lot code, microgram potency, and research-use designations per international standards such as GHS. Blotter sheets maintain uniformity and legibility of grid markings.
Recommended storage occurs at room temperature (15–25°C) in a desiccator or low-humidity cabinet, away from direct light and oxidizing agents to preserve long-term stability exceeding 24 months. Segregate from incompatibles like strong acids or bases. This configuration supports extended shelf life while facilitating precise retrieval for analytical workflows.
Intended Research Use & Market Positioning
This research chemical targets analytical chemistry, forensic reference standards, pharmaceutical R&D, and educational laboratory curricula focused on lysergamide synthesis and detection methodologies. Institutions employ it for calibration curves in GC-MS or LC-MS workflows, method validation under ISO 17025 accreditation, and spectral library expansion. Industrial R&D leverages its profile in developing novel detectors or impurity profiling assays.
Positioned for qualified buyers in academic, governmental, and private sector labs, 1V-LSD 150mcg Blotters fills a niche for high-purity, quantifiable reference materials amid growing demands for controlled substance analytics. Its blotter format enhances usability in microdosing analytical protocols, distinguishing it within generic reagent catalogs for precise, reproducible experimentation.
Ordering, Availability & Fulfillment
1V-LSD 150mcg Blotters remains in consistent stock for immediate fulfillment, accessible via secure eCommerce checkout with multiple payment options compliant for research institutions. Orders process within 24–48 hours, dispatched via tracked, discreet carriers ensuring temperature-controlled transit worldwide. Bulk or repeat orders qualify for volume pricing upon inquiry.
Dedicated customer support handles technical queries, COA requests, and compliance documentation Monday through Friday. Global shipping adheres to export regulations, with customs declarations specifying research-grade reagents. This streamlined process supports uninterrupted laboratory operations for time-sensitive projects.
Legal & Regulatory Disclaimer
1V-LSD 150mcg Blotters is sold strictly for research purposes only, not for human or veterinary use. Not for clinical, diagnostic, or consumptive applications. Buyers assume full responsibility for compliance with all applicable local, national, and international laws and regulations governing the purchase, possession, handling, and disposal of research chemicals. No representations are made regarding suitability for any specific application beyond laboratory research. Consult jurisdictional authorities and institutional review boards prior to acquisition. For research use only. Not for human or veterinary use. Not for clinical, diagnostic, or consumptive applications.
| Physical States |
Blotters |
|---|---|
| Quantity in Blotters |
10 ,100 ,25 ,5 ,50 |
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Reviews
There are no reviews yet.